Power range:
Features:
1. Advanced power electronic hardware design;Advanced technology of motor control, V/F control and vector control;Max. efficiency can reach 98%;
2.Deal with harsh environment condition of solar pump system IP65 design, against water and dust, enhance lifespan of system.
3.Run stably at a high temperature of 60℃.Start to derate operation over 60℃.
4.Use solar DC control technology comes from solar on-grid technology.Excellent MPPT efficiency, adapt to cloudy weather.With high efficiency, the system can maximize pump water.
Automatically set stop frequency. Automatically set the stop working point according to the minimum power of pump water, avoid the pump clogging and improve the system lifespan.
Simple forward and reverse design, the steering of the motor can be changed without changing the system wiring.Patented automatic pump dry protection, avoid the motor idling if the water level sensor fails.
Soft start & stop design, reduce the mechanical shock of pump start and stop.
Model
|
JNP550L-V5
|
JNP750L-V5
|
JNP1K1L-V5
|
JNP1K5L-V5
|
JNP2K2L-SE-V5
|
JNP2K2L-V5
|
JNP3KL-V5
|
JNP3K7L-V5
|
JNP4KL-V5
|
PV Input
|
|
|
|
|
|
|
|
|
|
D.C. Max. Input Voltage
|
450V
|
450V
|
450V
|
450V
|
450V
|
480V
|
480V
|
480V
|
480V
|
Recommended MPPT Voltage
|
80~400V
|
105~400V
|
130~400V
|
150~400V
|
150~400V
|
200~450V
|
200~450V
|
200~450V
|
200~450V
|
D.C. Max. Input Current
|
15A
|
15A
|
15A
|
15A
|
20A
|
15A
|
30A
|
30A
|
30A
|
Max. MPPT Effiffifficiency
|
>99%
|
>99%
|
>99%
|
>99%
|
>99%
|
>99%
|
>99%
|
>99%
|
>99%
|
Number of String
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
A.C. Input
|
|
|
|
|
|
|
|
|
|
Voltage
|
198~265Vac,1PH
|
198~265Vac,1PH
|
198~265Vac,1PH
|
198~265Vac,1PH
|
198~265Vac,1PH
|
198~264Vac,1PH
|
198~264Vac,1PH
|
198~264Vac,1PH
|
198~264Vac,1PH
|
Frequency
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
50Hz/60Hz(±3%)
|
A.C. Output
|
|
|
|
|
|
|
|
|
|
Max. Motor Output Power
|
0.55kW
|
0.75kW
|
1.1kW
|
1.5kW
|
2.2kW(3PH)/
1.5kW(1PH)
|
2.2kW
|
3kW(3PH)/
2.2kW(1PH)
|
3.7kW(3PH)/
2.2kW(1PH)
|
4kW(3PH)/
2.2kW(1PH)
|
Rated Output Voltage
|
220/230Vac (1PH or 3PH)
|
220/230Vac (1PH or 3PH)
|
220/230Vac (1PH or 3PH)
|
220/230Vac (1PH or 3PH)
|
220/230Vac (1PH or 3PH)
|
220/230Vac (1PH or 3PH)
|
220/230Vac (1PH or 3PH)
|
220/230Vac (1PH or 3PH)
|
220/230Vac (1PH or 3PH)
|
Output Frequency Range
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
Max.Output Current
|
5A
|
6A
|
9A
|
11A
|
13A
|
15A
|
|
|
|
System
|
|
|
|
|
|
|
|
|
|
Protection Level
|
IP65
|
IP65
|
IP65
|
IP65
|
IP65
|
IP65
|
IP65
|
IP65
|
IP65
|
Operating Temperature
|
-25~60℃
|
-25~60℃
|
-25~60℃
|
-25~60℃
|
-25~60℃
|
-25~60℃
|
-25~60℃
|
-25~60℃
|
-25~60℃
|
Cooling Way
|
Nature cooling
|
Nature cooling
|
Nature cooling
|
Nature cooling
|
Nature cooling
|
Nature cooling
|
Nature cooling
|
Nature cooling
|
Nature cooling
|
Display
|
RS485,GPRS/Bluetooth(without LCD) optional
|
RS485,GPRS/Bluetooth(without LCD) optional
|
RS485,GPRS/Bluetooth(without LCD) optional
|
RS485,GPRS/Bluetooth(without LCD) optional
|
RS485,GPRS/Bluetooth(without LCD) optional
|
RS485,GPRS/Bluetooth(without LCD) optional
|
RS485,GPRS/Bluetooth(without LCD) optional
|
RS485,GPRS/Bluetooth(without LCD) optional
|
RS485,GPRS/Bluetooth(without LCD) optional
|
Altitude
|
3000m, above3000m need derate operarting
|
3000m, above3000m need derate operarting
|
3000m, above3000m need derate operarting
|
3000m, above3000m need derate operarting
|
3000m, above3000m need derate operarting
|
3000m, above3000m need derate operarting
|
3000m, above3000m need derate operarting
|
3000m, above3000m need derate operarting
|
3000m, above3000m need derate operarting
|
Noise Emission
|
<50dB
|
<50dB
|
<50dB
|
<50dB
|
<50dB
|
<50dB
|
<50dB
|
<50dB
|
<50dB
|
Compliance
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
Dimension(W/H/D)
|
265/330/150(mm)
|
265/330/150(mm)
|
265/330/150(mm)
|
265/330/150(mm)
|
265/330/150(mm)
|
265/330/150(mm)
|
265/330/150(mm)
|
265/330/150(mm)
|
265/330/150(mm)
|
Weight
|
6.5kg
|
6.5kg
|
6.5kg
|
6.5kg
|
6.5kg
|
6.5kg
|
6.5kg
|
6.5kg
|
6.5kg
|
|
|
|
|
|
|
|
|
|
|
ISO9001, IS014001, OHSAS18001,TUV,CE,AAA credit management system,Third level qualification of power project construction, National high-tech enterprises