Application:
Areas without electricity, low power,unstable power grids,and high electricity prices where solar air conditioner is in demand.
Application:
Areas without electricity, low power,unstable power grids,and high electricity prices where solar air conditioner is in demand.
Solar Air Conditioner is the perfect solution for people who live around the tropics and areas which suffered from heat from the sunlight. Also, in the high-dimensional region, the sunshine duration in summer would be much longer than the normal region, further, in this particular time of the greenhouse effect, global temperature has continually increased in the past decades. Summer with sunshine heating and high temperature has been a nightmare to people who live in the high-dimensional region.
(All models have both DC Solar Energy Typechioce)
Solar& AC hybrid Conditioner system suggested configuration |
||||
Model |
Power input (w) average |
Work Time (h) solar time |
Solar Panel |
Application area (m²) |
JNSAC-HS-12000BTU |
800 |
9 |
340W*4 |
15~20 |
JNSAC-HS-18000BTU |
1300 |
8 |
340W*6 |
20~30 |
JNSAC-HS-24000BTU |
1700 |
8 |
340W*8 |
32~42 |
Model |
Unit |
|
JNSAC12000-V2 |
JNSAC18000-V2 |
JNSAC24000-V2 |
Power Supply |
AC Power |
Ph-V-Hz |
1Ph 208V-240V/50-60HZ |
1Ph 208V-240V/50-60HZ |
1Ph 208V-240V/50-60HZ |
DC Power (PV in Series) |
V |
80-380V |
80-380V |
80-380V |
|
DC Power Current |
A |
</=12A |
</=12A |
</=12A |
|
Adviced Solar Panel |
Pcs |
(3-4)*330W in series |
(3-6)*330W in series |
(3-8)*330W in series |
|
Rated Cooling |
Capacity |
W |
3510(900-3900) |
5070(1200-6000) |
6450(1800-7900) |
BTU |
12000(3000-13300) |
17300(4100-20400) |
22000(6100-27000) |
||
Power input |
W |
940(190-1270) |
1400(220-2100) |
1790(300-3200) |
|
Rated Heating |
Capacity |
W |
4100(1000-4500) |
6100(1200-6800) |
7800(1800-9100) |
Power input |
W |
1170(190-1700) |
1770(220-2500) |
2290(300-3500) |
|
T1 EER (W/W)/ (BTU/W) |
/ |
3.75/12.75 |
3.60/12.35 |
3.60/12.30 |
|
COP (W/W)/ (BTU/W) |
/ |
3.50/11.95 |
3.45/11.75 |
3.40/11.60 |
|
Dehumidification capacity |
L/h |
1.3 |
1.7 |
2.5 |
|
Indoor noise level (Turbo) |
dB(A) |
42.5 |
46 |
50 |
|
Indoor unit |
Dimension(W×H×D) |
mm |
840×205×295 |
1080×330×237 |
1080×330×237 |
Packing (W×H×D) |
mm |
920×290×360 |
1140×300×382 |
1140×300×382 |
|
Net weight/Gross weight |
Kg |
9.0/12.5 |
15.0/18.5 |
15.0/18.5 |
|
Outdoor noise level |
dB(A) |
52 |
55 |
58 |
|
Outdoor unit |
Dimension(W×H×D) |
mm |
802×564×323 |
802×564×323 |
900×700×337 |
Packing (W×H×D) |
mm |
910×622×405 |
910×622×405 |
1006×755×418 |
|
Net/Gross weight |
Kg |
33.5/37.5 |
37/42.0 |
50/54.5 |
|
Refrigerant type |
/ |
R410A |
R410A |
R410A |
|
Max Design pressure |
MPa |
4.3/1.5 |
4.3/1.5 |
4.3/1.5 |
|
Refrigerant copper pipe |
Gas side/Liquid side (inch) |
inch |
3/8 1/4 |
1/2 1/4 |
1/2 1/4 |
Max. refrigerant pipe length |
m |
15 |
20 |
25 |
|
Max. difference in level |
m |
8 |
10 |
10 |
|
Refrigerant connction copper pipe length |
m |
3 |
4 |
4 |
|
Connection wire length |
m |
4 |
5 |
5 |
|
Electronic Expansion Valve |
/ |
Yes |
Yes |
Yes |
|
Loading QTY 40" Hq/ 20"GP |
Sets |
200/85 |
160/75 |
115/50 |
|
Application area |
m² |
15~20 |
20~30 |
32~42 |
Solar air conditioner application
Real shooting of production line