System Features:
1.Safety
Overload and short circuit protection;
Auto restart while AC is recovering;
Compatible to mains voltage or generator power;
2.Smart
Perfect pure sine wave output;
Selectable charging current;
Configurable AC/ DC input priority via LCD setting;
3.Reliable
Built-in pure copper transformer;
Silicon-controlled rectifier(SCR) be adopted in AC by-pass;
Provide power supply to load for 24 hours;
4.Intelligent
Advanced battery management system (BMS);
Support sealed battery and lithium battery;
Special AC output design, adopt emergency ; heavy loads separate control.
Introduction
High Integrated with inverter, AC charger, solar charge controller and AC by pass.
Intelligent management system of AC charger and PV charging controller, AC optional and AC output self-contained energy management system, which can ensure the normal power consumption and reduce the cost of electricity bill.
-
ECO and UPS model, satisfy different energy demand.
-
Grid pass-by and converting switch time 0ms,fast switching.
-
LCD depth optimization, intuitive display of machine operation status, easy to operate.
The products are mainly used for short-term and long-term power supply in areas without or lack of electricity.
Subject/mode
|
JNF3KLF24V-V2
|
JNF3KLF48V-V2
|
JNF4KLF48V-V2
|
JNF5KLF48V-V2
|
PV input
|
PV max. input dc voltage
|
150Vdc
|
Recommended PV Capacity
|
3500W
|
5000W
|
7000W
|
7000W
|
MPPT range
|
35~145Vdc
|
65~145Vdc
|
65~145Vdc
|
65~145Vdc
|
Storage battery
|
Rated voltage
|
24Vdc
|
48Vdc
|
48Vdc
|
48Vdc
|
Max. charging current
|
80A
|
60A
|
80A
|
80A
|
Charging efficiency
|
≥97%
|
Battery type
|
Gel/lithium
|
Inverter output
|
Rated output capacity
|
3000VA
|
3000VA
|
4000VA
|
5000VA
|
Rated output power (linear load)
|
3000W
|
3000W
|
4000W
|
5000W
|
Output voltage
|
220Vac
|
220Vac
|
220Vac
|
220Vac
|
Rated frequency
|
50/60Hz (±3%)
|
Standby loss
|
≤10W
|
Max. efficiency
|
93%
|
Output waveform
|
Pure sine wave
|
THD
|
<3%
|
Rated current
|
13.5A
|
13.5A
|
18A
|
22.5A
|
Peak current factor
|
3:1
|
Overload
|
125%@rated power, 70s;150%@rated ,20s; 200%@rated ,5s;over 300%@rated,0s.
|
Grid input
|
Grid input voltage
|
230Vac±20%
|
Grip input frequency
|
50/60Hz (±3%)
|
Max. charging current
|
30A
|
40A
|
40A
|
40A
|
Power grid bypass
|
Allowed input voltage
|
230Vac±20%
|
230Vac±20%
|
230Vac±20%
|
230Vac±20%
|
Switching time
|
<10ms
|
Machine parameters
|
Dimension(W/H/D)
|
440mm*370mm*190mm
|
Weight
|
28Kg
|
28kg
|
30kg
|
33kg
|
Others parameters
|
Protection lever
|
IP20
|
Noise
|
<60dB
|
Cooling method
|
Forced air cooling
|
Working temperature
|
-20~+50℃
|
Storage temperature
|
-25~+70℃
|
Status indicator
|
LCD+LED
|
Interface
|
RS485/CAN (Optional)
|
Altitude height
|
2000m(>2000m derating)
|
Send your message to this supplier