ECP mahine with CE approval
ECP machine is widely used in angina heart disease, male sexual dysfunction, early high blood diseases, high blood sugar and poor blood circulation caused vertigo, dizziness, cervical spondylosis and physical fatigue.
Omay ECP Features:
1.The most important hardware accessories like compressor and valves are imported from Germany and Taiwan famous company.Compressor with a liftspan more than 10years.
2.Omay ECP with remote dignosis function,which enable us to diagnose and solve any software problems in our factory
3.The deflation and inflation time can be adjustable based on different patients.
4.With customer managerment system,can save and print out each patients data.
5. With"demostrate function",will automatically check whether all systems are properly working before doing treatment for patients.
6.Real-time ECG and SpO2 monitor function during treatment,showing the D/S ratio,intuitive observation of treatment effect.
7.It adopts scientific designed system to reduce noise and heat.
8.High efficiency cuffs for energy-saving:low pressure can generate high treatment effect
9.Stable and durable industrial personal computer adopted
10.Stable software system:Embedded software system,virus can’t attack.
11.The angle of the backrest can be adjusted on the basis of patient's physiological situation.
12.Omay ECP: got US FDA, CE, ISO13485 and SFDA
Omay ECP machine Technical Parameter:
1.The ECG Amplifier has 20Hz Band Width, > 2MΩ input impendence and > 80db CMRR.
2.The system triggers the R-Wave of Pt. ECG externally with a ratio of 1:1 / 1:2 and 35 to 125 bpm.
3.Oxygen saturation range from 0 to 100% with a standard deviation of 3 digits using Finger Clip Senor.
4.Low-pass digital filter eliminates 50/60Hz and high-frequency.
5.Single key operation for controlling the pressure from 5 to 350 mmHg.Omay ECP can be used for adult as well as kids
6.Three different sizes of Cuffs for Calves, lower and upper thighs.
7.The Timer is provided for setting the treatment session and the device stops automatically on the expiry of the “set” time.
8.The circuit breakers will actuate for the system protection and an Emergency Stop Button is also provided for patient safety.Three circuit breakers-Mains,compressor and an emergency stop.
9.In case of any of the following reasons, the inflation will stop and the pressure gets released:
i) An early systole.
ii) Power Supply failure.
iii) The pressure crosses 350 mmHg.
iv) Heart Rate goes out of range <35 bpm or >125 bpm.
v) Emergency Stop is operated by the patient.
10.Dimension:211x96x96cm,weight:220KG
11.Power Requirement:- 220 v ac ± 10%, 50/60 Hz, 1350 W.
12.Environmental Conditions:- Free from corrosive gases.
Temperature : -10° C to 40° C.
Relative Humidity : <80% without condensation.
Atmospheric Pressure: 700 to 1060 hPa.
13.Transportation and Storage Conditions:- Corrosive gases free Atmosphere.
Temperature : -10° to 60° C.
Relative Humidity : <85% without condensation.
Atmospheric Pressure: 500 to 1060 hPa.