2KW Off-Grid Inverter
Corigy off-grid inverter is suitable for RV systems, off-grid
households, communication base stations, island border defense, power
stations, etc.
Model No. |
CP-2K-U2024100-A60 |
Mains Electricity Mode |
|
Rated Output Voltage |
220/230Vac |
Input Voltage Range |
(170~280Vac)±2%; (90~280Vac)±2% |
Frequency |
50/60Hz(Auto Detect) |
Frequency Range |
47±0.3Hz~55±0.3Hz(50Hz)/57±0.3Hz~65±0.3Hz(60Hz) |
Overload/ Short Circuit Protection |
Breaker |
Efficient |
>95% |
Conversion time (Bypass and Invert) |
10ms (Typical Value) |
AC Current Flow-Backwards Protection |
Yes |
Max Bypass Overcurrent |
30A |
Inverter Mode |
|
Output Voltage Waveform |
Pure Sine Wave |
Rated output power (VA) |
2000 |
Rated output power (W) |
2000 |
Power Factor |
1 |
Rated output voltage (Vac) |
230Vac |
Output Voltage Error |
±5% |
Output Frequency Range (Hz) |
50Hz±0.3Hz/60Hz±0.3Hz |
Max Efficiency |
>92% |
Overload Protection |
(102%<Load<125%)±10%:Report the error and close the output after 5 minutes; (125%<Load<150%)±10%:Report the error and close the output after 10 seconds; Load>150%±10%:Report the error and close the output after 5 seconds |
Peak Power |
4000 |
On-Load Motor Capacity |
1HP |
Output Short Circuit Protection |
Breaker |
Bypass Breaker Specifications |
30A |
Rated Battery Input Voltage |
24V(Minimum starting voltage 22V) |
Battery Voltage Range |
20.0Vdc~33Vdc ±0.6Vdc (LCD screen can be set for under-voltage alarm/shutdown voltage/over-voltage alarm/over-voltage recovery) |
Power Saving Mode |
Load≤50W |
Mains Electricity Charging |
|
Battery Type |
Lead acid or lithium battery |
Max Charging Current |
60A |
Charge Current Error |
±5Adc |
Charging Voltage Range |
20.0Vdc~33Vdc |
Short Circuit Protection |
Breaker or blow fuse |
Breaker Specifications |
30A |
Overcharge Protection |
Warn and turn off charging after 1 minute |
Solar Charging |
|
Max PV Open Circuit Voltage |
100Vdc |
PV Operating Voltage Range |
30~100Vdc |
MPPT Voltage Range |
30~85Vdc |
Battery Voltage Range |
20~33Vdc |
Max Output Power |
1400W |
Solar Charging Current Range (Can Be Set) |
0-60A |
Charging Short Circuit Protection |
Blow fuse |
Wiring Protection |
Reverse polarity protection |
Certifications |
|
Specification Certification |
CE(EN62109-1) |
EMC Certification Grade |
EN61000,C2 |
Working Temperature Range |
-15℃ to 55℃ |
Storage Temperature Range |
-25℃ to 60℃ |
Humidity Range |
5% to 95% (Conformal Coating Protection) |
Noise |
≤60dB |
Cooling |
Strong cooling air,Adjustable wind speed |
Communication Interface |
USB/RS485(WiFi/GPRS)/Dry contact control |
Dimensions (L*W*D) |
378*280*103mm |
Weight (Kg) |
6.2KG |
-Pure sine wave inverter
-Output power factor 1
-High PV input voltage range
-Inverter running without battery
-Bulit -in MPPT solar charge.
-Bulit-in anti-dusk kit for harsh environment