Availability :
OEM/ODM, Minmum Order RequestPackage :
Standard Export Package Carton/WoodTransportation :
Express · Sea freight · Land freight · Air freightWarranty :
18 MonthsDelivery Time :
5-7 working days for standard series; 7-14 working days for customized AC drivesCustomized :
YESTerm of payment :
T/T, L/C, D/PSample freight payer :
BuyerSample provide :
YESPlace of Origin :
ChinaShipping Port :
ShenzhenCertification :
CE, EAC, ISO9001, OHSAS18001, TS16949, SGS
Product Overview
Item
Description
Product Name
Frequency Inverter/ AC Drive
Model Number
V9-H-4TxxG/xxL
Power Range
0.75kW-630kW
Rated Input Voltage
3 phase 380V/480V
Rated Output Voltage
3 phase 0 to rated input voltage
Input Frequency
50Hz/60Hz
Adaptable Motor
Asynchronous Motor, Synchronous Motor
Control Mode
V/F Control, Vector Control, Sensorless Vector Control, Sensor Vector Control, Vector Torque Control
Communication
Modbus 485 RTU, CANOpen, Profibus-DP, Profinet
IP Class
Standard IP20
Overload Capacity
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)
Feature
■ Fast and accurate motor parameter self-learning, suitable for a variety of motors: synchronous/asynchronous/reluctance/high-speed/torque motor, VF vector encoder closed loop integrated
■ Asynchronous and non-inductive VF control, 200% torque output at 0.25Hz in electric state, 200% torque output at 1Hz in power generation state
■ Good voltage and current control, high speed, high frequency, deep field weakening, wave-by-wave current limiting, multiple protections
■ Modular compact structure design, high power density
■ Support multiple encoders and multiple high-speed communication protocols
■ Integrated drive and control, expandable PLC and motion control card
■ Multiple language keyboard, friendly interface, reliable and easy to use
Model Explanation
Product Catalogue
V9−H−4T□□□G ;Three-phase 400V constant torque / heavy duty Application
Power(kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
Motor power (kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
Output
Voltage (V)
3-phase 0 -rated input voltage
Rated current (A)
2.5
3.8
5.5
9
13
17
24
30
39
45
60
75
91
112
150
176
210
Overloa capability
150% 1min,180% 10s, 200% 0.5s,10min interval (Inverse-time characteristic)
Input
Rated voltage / frequency
3-phase 380V-480V;50Hz/60Hz
Allowabl voltage
323V-528V;degree of voltage unbalance:≤3%;allowable frequency fluctuations:±5%
Rated current (A)
2.8
4.2
6.1
10
15
19
26
33
43
50
66
83
100
123
165
194
231
Brake unit
Standard built-in
Built-in brake unit is optional
Protection level
IP20
Cooling method
Self−cooling
Forced cooling
Power(kW)
132
160
185
200
220
250
280
315
355
400
450
500
560
630
Motor power (kW)
132
160
185
200
220
250
280
315
355
400
450
500
560
630
Output
Voltage (V)
3-phase 0 -rated input voltage
Rated current (A)
253
304
350
380
426
470
520
600
650
690
775
860
950
1100
150% 1min,180% 10s, 200% 0.5s,10min interval (Inverse-time characteristic)
Input
Rated voltage / frequency
3-phase 380V-480V;50Hz/60Hz
Allowable voltage
323V-528V;degree of voltage unbalance:≤3%;allowable frequency fluctuations:±5%
Rated current (A)
232
282
326
352
385
437
491
580
624
670
755
840
920
1050
Brake unit
External braking unit needed
Protection level
IP20
Cooling method
Forced cooling
Note:* 0.75kW~15kW:no built-in DC reactor ;
18.5kW~110kW:optional DC reactor ;
132kW~160kW:standard built-in DC reactor ;
185kW~500kW:standard external DC reactor
560kW~630kW:standard built-in AC input reactor
Higher power level product can be customized
220V, 690V, 1140V and other voltage level inverters can be customized
V9−H−4T□□□L ;Three−phase 400V Variable torque/light−duty Application
Power(kW)
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
Motor power (kW)
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
Output
Voltage(V)
3-phase 0 -rated input voltage
Rated current (A)
3.3
5
7.5
11
17
22
29
35
45
57
70
91
110
144
180
216
242
Overload capability
120% 1min,160% 0.5s,10min interval (Inverse-time characteristic)
Input
Rated voltage /frequency
3-phase 380V-480V;50Hz/60Hz
323V-528V;degree of voltage unbalance:≤3%;allowable frequency fluctuations:±5%
Rated current (A)
3.6
5.5
8.3
12
19
25
32
39
50
61
77
100
121
158
198
238
266
Brake unit
Standard built-in
Built-in brake unit is optional
Protection level
IP20
Cooling method
Self−cooling
Forced cooling
Power(kW)
160
185
200
220
250
280
315
355
400
450
500
560
630
710
Motor power (kW)
160
185
200
220
250
280
315
355
400
450
500
560
630
710
Output
Voltage (V)
3-phase 0 -rated input voltage
325
365
405
440
495
547
610
695
770
866
950
1100
1200
1300
Overload capability
120% 1min,160% 0.5s,10min interval (Inverse-time characteristic)
Input
Rated voltage /frequency
3-phase 380V-480V;50Hz/60Hz
323V-528V;degree of voltage unbalance:≤3%;allowable frequency fluctuations:±5%
Rated current (A)
282
326
352
385
437
491
580
670
755
840
920
1050
1150
1250
Brake unit
External braking unit needed
Protection level
IP20
Cooling method
Forced cooling
Note: * 1.5kW - 18.5kW: no built-in DC reactor ;
200kW~560kW: standard external DC reactor ;
22kW~132kW: optional DC reactor ;
160kW~185kW: standard built-in DC reactor ;
630kW~710kW: standard built-in AC input reactor
Higher power level product can be customized ;
220V, 690V, 1140V and other voltage level inverters can be customized
Technical Specification
Control characteristics |
Control mode |
Sensor-less control |
Sensor control |
Applicable motor type |
Synchronous motor Asynchronous motor |
Synchronous motor Asynchronous motor |
|
Starting torque |
● Asynchronous ;motor: 200% of rated torque at 0.25Hz ● Synchronous ;motor: 150% of rated torque at 1.5% of rated speed
|
200% of rated torque at 0 speed |
|
Speed regulation range |
1:200 |
1:5000 |
|
Steady speed precision |
± 0.5% |
± 0.02% |
|
Maximum speed |
VF control: 600Hz Vector control: ;600 Hz ;
Note: Higher frequency products can be customized |
600Hz Note: Higher ;frequency ;products can be customized |
|
Torque control |
Y |
Y |
|
Torque control precision |
±5% |
±3% |
|
Torque response time |
<20ms |
<10ms |
|
Positioning control |
N |
Y |
|
Positioning ;precision |
N |
±1 ;pulse |
|
Product function |
Key function |
Torque limit, speed control, positioning control, motor ;auto tune, ;deep ;flux-weakening ;control, current limit control, over-voltage control, under-voltage control, ;motor ;speed tracing function, droop control, oscillation suppression, random carrier frequency, inertia auto-tune, etc. |
|
Speed reference source |
Modbus communication, Keypad, ;external digital input, analog ;AI1/AI2/AI3, ;high speed pulse input, ;simple PLC, PID, ;CAN, PROFIBUS DP, PROFINET, ;etc. |
||
Dynamic brake |
Brake unit action voltage: 650 ~ 750V. The brake unit can be built-in for ;110kW ;and below equipment ● ;0.75~15kW: brake unit is built- in as standard. ● ;18.5~110kW: brake unit is built- in as optional. |
||
Communication |
Built-in ;Modbus-RTU communication, the maximum distance up to 500 meters. |
||
Keypad |
LED Keypad and LCD Keypad are optional the Keypad can be used as ;remote-control box ;via straight-through wired cable. ; |
||
Common DC bus |
Support common DC bus ;directly |
||
Independent air duct |
All series product adopts independent duct design |
||
Protection function |
Power supply under-voltage, over-current protection, over-voltage protection, ;auto-tune fault, module protection, heat-sink overtemperature ;protection, drive overload protection, motor overload protection, peripheral protection, current ;abnormal ;detection, output short-circuit ;to ;ground protection, EEPROM abnormal detection, temperature sampling disconnection, encoder disconnection, analog input abnormal detection, motor overtemperature, communication ;fault, hardware overload protection, etc. |
||
Efficiency |
At rating condition: ● ;0.75kW to ;7.5kW: ;≥93% ● ;11kW to ;45kW: ;≥95% ● ;55kW and ;higher ;power class: ;≥98% |
||
Environment |
Operating site |
● ;Install vertically in a well-ventilated electrical cabinet. Horizontal or other installation methods are not allowed. ● ;The cooling medium is air. ● Installed in an environment free from direct sunlight, dust, corrosive gases, flammable gases, no oil mist, no steam, no dripping. |
|
Ambient temperature |
● ;−10~+40℃ ● ;Derating use when the temperature between 40 to 50℃, the rated output current is reduced by 1% for every 1 °C increasing. |
||
Humidity |
5~95%, ;no condensation is allowed. |
||
Altitude |
● ;0~2000 ;meters ● ;Derating use when the altitude over 1000 meters, the rated output current is reduced by 1% for every 100-meter rising. |
||
Vibration |
● ;3.5 m/s2, ;2~9Hz ● ;10 m/s2, ;9~200Hz ● ;15 m/s2, ;200~500Hz |
||
Storage temperature |
−40~+70℃. |
Installation dimension
|
|
V9−H−4T7.5G/11L and below power class
|
|
V9−H−4T11G/15L and above power class
Voltage |
Model |
Outline and mounting dimension (mm) |
Weight (kg) |
||||||
W |
H |
D |
W1 |
H1 |
T1 |
Mounting hole diameter ;d |
|||
400V |
V9−H−4T0.75G/1.5L |
118 |
190 |
155 |
105 |
173 |
3 |
5.5 |
1.5 |
V9−H−4T1.5G/2.2L |
118 |
190 |
175 |
105 |
173 |
4 |
5.5 |
2.6 |
|
V9−H−4T2.2G/3.7L |
|||||||||
V9−H−4T3.7G/5.5L |
|||||||||
V9−H−4T5.5G/7.5L |
155 |
249 |
185 |
136 |
232 |
8 |
5.5 |
3 |
|
V9−H−4T7.5G/11L |
|||||||||
V9−H−4T11G/15L |
198 |
299 |
190 |
160 |
283 |
1.2 |
6 |
8 |
|
V9−H−4T15G/18.5L |
|||||||||
V9−H−4T18.5G/22L |
223 |
348 |
208 |
195 |
335 |
1.5 |
6 |
10 |
|
V9−H−4T22G/30L |
|||||||||
V9−H−4T30G/37L |
264 |
430 |
235 |
230 |
418 |
1.5 |
7 |
18 |
|
V9−H−4T37G/45L |
|||||||||
V9−H−4T45G/55L |
305 |
545 |
270 |
245 |
523 |
1.5 |
10 |
35 |
|
V9−H−4T55G/75L |
|||||||||
V9−H−4T75G/90L |
338 |
580 |
310 |
270 |
560 |
1.5 |
10 |
52 |
|
V9−H−4T90G/110L |
|||||||||
V9−H−4T110G/132L |
|||||||||
V9−H−4T132G/160L |
400 |
917 |
323 |
320 |
890 |
3.0 |
12 |
75 |
|
V9−H−4T160G/185L |
|||||||||
V9−H−4T185G/200L |
540 |
890 |
385 |
370 |
855 |
4.0 |
14 |
85 |
|
V9−H−4T200G/220L |
|||||||||
V9−H−4T220G/250L |
540 |
890 |
416 |
370 |
855 |
4.0 |
14 |
85 |
|
V9−H−4T250G/280L |
700 |
1010 |
385 |
520 |
977 |
4.0 |
14 |
125 |
|
V9−H−4T280G/315L |
|||||||||
V9−H−4T315G/355L |
700 |
1010 |
418.5 |
520 |
977 |
4.0 |
14 |
125 |
|
V9−H−4T355G/400L |
810 |
1358 |
425 |
520 |
1300 |
4.0 |
14 |
215 |
|
V9−H−4T400G/450L |
810 |
1358 |
425 |
520 |
1300 |
4.0 |
14 |
215 |
|
V9−H−4T450G/500L |
|||||||||
V9−H−4T500G/560L |
Applications
|
|
|
|
|
|
|
|
|