INTRODUCTION
This soalr pump inverter is specially designed for field irrigation,drinking water in small towns pump system,using hybrid design with solar and utility/DG Energy online complementation.
Features:
1. It has strong overload capability and can drive the 3ph/1ph pump ;
2. Super MPPT function, efficiency >99%;wide range of MPPT input voltage ranges;
4. IP65 and fanless design,aluminium casting,outdoor use, adapt to harsh application environments;
5. RS485 and GPRS remote monitoring and start-stop management through APP;
6.Meet the simultaneous input of the utility Grid/DG and solar, automatic switching, online energy complementary, solar priority, keep the pump rated work, and achieve 24H water supply.
7.Perfect system protection, undervoltage, overload, overvoltage, overcurrent, grid phase loss, pump dry, phase loss, short circuit, overheating, etc.
8.Fully automatic operation control, soft start and soft stop,one key to start.
Item\ Model
|
JNP2K2H-V6
|
JNP3KH-V6
|
JNP3K7H-V6
|
JNP4KH-V6
|
JNP5K5H-V6
|
JNP7K5H-V6
|
DC input
|
|
|
|
|
|
|
Max. input DC voltage
|
880V
|
880V
|
880V
|
880V
|
880V
|
880V
|
Recommended MPPT voltage
|
460~850V
|
460~850V
|
460~850V
|
460~850V
|
460~850V
|
460~850V
|
Max. input DC current
|
15A
|
15A
|
15A
|
15A
|
30A
|
30A
|
MPPT efficiency
|
>99%
|
>99%
|
>99%
|
>99%
|
>99%
|
>99%
|
Max. input DC voltage
|
1
|
1
|
1
|
1
|
1
|
1
|
Utility/diesel input parameters
|
|
|
|
|
|
|
VDC
|
360~460Vac (3PH)
|
360~460Vac (3PH)
|
360~460Vac (3PH)
|
360~460Vac (3PH)
|
360~460Vac (3PH)
|
360~460Vac (3PH)
|
Frequency
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
50Hz/60Hz
|
AC output side
|
|
|
|
|
|
|
Max. matching motor power
|
2.2kW
|
3kW
|
3.7kW
|
4kW
|
5.5kW
|
7.5kW
|
Rated Output Voltage
|
380~460Vac (3PH)
|
380~460Vac (3PH)
|
380~460Vac (3PH)
|
380~460Vac (3PH)
|
380~460Vac (3PH)
|
380~460Vac (3PH)
|
Frequency output range
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
0~50/60Hz
|
Rated output current
|
6A
|
7A
|
9A
|
10A
|
13A
|
18A
|
System
|
|
|
|
|
|
|
Level of protection
|
IP65
|
IP65
|
IP65
|
IP65
|
IP65
|
IP65
|
Operating ambient temperature range
|
-25~60℃
|
-25~60℃
|
-25~60℃
|
-25~60℃
|
-25~60℃
|
-25~60℃
|
Type of cooling
|
natural cooling
|
natural cooling
|
natural cooling
|
natural cooling
|
natural cooling
|
natural cooling
|
Display
|
LCD
|
LCD
|
LCD
|
LCD
|
LCD
|
LCD
|
Communication
|
RS485/GPRS
|
RS485/GPRS
|
RS485/GPRS
|
RS485/GPRS
|
RS485/GPRS
|
RS485/GPRS
|
Altitude
|
3000m, downscaling operation above 3000m
|
3000m, downscaling operation above 3000m
|
3000m, downscaling operation above 3000m
|
3000m, downscaling operation above 3000m
|
3000m, downscaling operation above 3000m
|
3000m, downscaling operation above 3000m
|
Noise
|
<50dB
|
<50dB
|
<50dB
|
<50dB
|
<50dB
|
<50dB
|
Meet acriterion
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
EN 50178; IEC/EN 62109-1;IEC61800
|
Specification size (W/H/D)
|
265/330/150(mm)
|
265/330/150(mm)
|
265/330/150(mm)
|
265/330/150(mm)
|
265/330/150(mm)
|
265/330/150(mm)
|
Weight
|
11.8kg
|
11.8kg
|
11.8kg
|
11.8kg
|
11.8kg
|
11.8kg
|
ISO9001, IS014001, OHSAS18001,TUV,CE,AAA credit management system,Third level qualification of power project construction, National high-tech enterprises