Item
Description
Product Name
Frequency Inverter/ AC Drive
Model Number
V5-H-4TxxG/xxL
Power Range
0.75kW-75k0W
Rated Input Voltage
3 phase 380V/480V
Rated Output Voltage
3 phase 0 to rated input voltage
Input Frequency
50Hz/60Hz
Adaptable Motor
Asynchronous Motor
Control Mode
V/F Control, Vector Control, Sensorless Vector Control, Vector Torque Control
Communication
Modbus 485 RTU
IP Class
Standard IP20
Overload Capacity
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)
Feature
■ Open loop vector control technology with high performance.
■ Inverter operates stably without tripping under any acceleration and deceleration time and any impact load.
■ Independent input and output port of high speed pulse, which can realize high speed pulse cascade function.
■ Accurate speed identification and rotor flux orientation, the torque can also respond quickly and operate stably when a load of 0.25hz breaks.
■ High-precision current detection and protection, high-precision hall to detect output current, realization of fast real-time control and protection of software and hardware, and assurance of performance and reliability of the whole machine.
Model Explanation
Product Catalogue
V5−H−4T□□□G Three-phase 400V Constant torque/heavy-duty application
*V5−H−4T90G and higher power products are equipped with external DC reactor as standard.
Power (kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
Motor power (kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
Output
Voltage (V)
Three-phase 0 to rated input voltage
Rated current (A)
2.5
3.8
5.5
9
13
17
24
30
39
45
60
75
91
112
150
Overload capacity
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag ;feature)
Input
Rated voltage/frequency
Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage range
323V ~ 528V; Voltage imbalance ;≤3%; allowable frequency fluctuation: ±5%
Rated current (A)
2.8
4.2
6.1
10
15
19
26
33
43
50
66
83
100
123
165
Braking unit
Built-in as standard
Built-in as option
Protection class
IP20
Cooling mode
Natural−cooling
Forced air cooling
Power (kW)
90
110
132
160
185
200
220
250
280
315
355
400
450
500
Motor power (kW)
90
110
132
160
185
200
220
250
280
315
355
400
450
500
Output
Voltage (V)
Three-phase 0 to rated input voltage
Rated current (A)
176
210
253
304
350
380
426
470
520
600
650
690
775
860
Overload capacity
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag ;feature)
Input
Rated voltage/frequency
Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage range
323V ~ 528V; Voltage imbalance ;≤3%; allowable frequency fluctuation: ±5%
Rated current (A)
160*
196*
232*
282*
326*
352*
385*
437*
491*
580*
624*
670*
755*
840*
Braking unit
External braking unit needed
Protection class
IP20
Cooling mode
Forced air cooling
V5−H−4T□□□L Three-phase 400V Variable torque/light-duty application
*V5−H−4T110L and higher power products are equipped with external DC reactor as standard.
Power (kW)
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
Motor power (kW)
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
Output
Voltage (V)
Three-phase 0 to rated input voltage
Rated current (A)
3.3
5
7.5
11
17
22
30
37
44
56
72
91
110
142
176
Overload capacity
115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)
Input
Rated voltage/frequency
Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage fluctuation range
323V ~ 528V; Voltage imbalance: ≤3%; allowable frequency fluctuation: ±5%
Rated current (A)
3.6
5.5
8.3
12
19
25
33
40
50
62
80
100
121
156
194
Braking unit
Built-in as standard
Built-in is optional
Protection class
IP20
Cooling mode
Natural cooling
Forced air cooling
Power (kW)
110
132
160
185
200
220
250
280
315
355
400
450
500
560
Motor power (kW)
110
132
160
185
200
220
250
280
315
355
400
450
500
560
Output
Voltage (V)
Three-phase 0 to rated input voltage
Rated current (A)
210
253
304
350
380
426
470
520
600
650
690
775
860
950
Overload capacity
115% 1 minute, 160% 0.5 second, interval: 10 minutes (inverse time lag feature)
Input
Rated voltage/frequency
Three-phase 380V/480V; 50Hz/60Hz
Allowable voltage range
323V ~ 528V; Voltage imbalance ;≤3%; allowable frequency fluctuation: ±5%
Rated current (A)
196*
232*
282*
326*
352*
385*
437*
491*
580*
624*
670*
755*
840*
920*
Braking unit
External braking unit needed
Protection class
IP20
Cooling mode
Forced air convection cooling
V5−H−2T□□□G Single/Three-phase 200V Constant torque/heavy-duty application
Power (kW) | 0.4 | 0.75 | 1.5 | 2.2 | |
Motor power (kW) | 0.4 | 0.75 | 1.5 | 2.2 | |
Output | Voltage (V) | Three-phase 0 to rated input voltage | |||
Rated current (A) | 3 | 5 | 7.5 | 10 | |
Overload capacity |
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes ;
(inverse time lag feature)
|
||||
Input | Rated voltage/frequency | Three-phase or single-phase 200V~240V; 50Hz/60Hz | |||
Allowable voltage range | 180V ~ 260V; Voltage imbalance ≤3%; allowable frequency fluctuation: ±5% | ||||
Rated current (A) | 3.8 | 5.5 | 8.3 | 12 | |
*Braking unit | Built-in as standard | ||||
Protection class | IP20 | ||||
Cooling mode | Natural-cooling | Forced air cooling |
Technical Specification
Control characteristics |
Control mode |
Vector control 1 |
Vector control 2 (Without encoder) |
Starting torque |
0.50Hz 180% |
0.25Hz 180% |
|
Range of speed regulation |
1:100 |
1:200 |
|
Precision of steady speed |
± 0.5% |
± 0.2% |
|
Product functions |
Key functions |
Under-voltage regulation, switchover of run command source(operation panel, terminal and communication), speed tracing function, torque limit, multi− step frequency reference(up to 23 step frequency), motor data identification, S curve acceleration and deceleration, slip compensation, PID regulation, droop control, current limit, switch-over between torque control and speed control, manual torque boost and auto torque boost, programmable digital inputs and programmable digital outputs |
|
Frequency reference mode |
Parameter setting, operation panel UP/DN, terminal, terminal UP/DN, communication, analog ( AI1/AI2/AI3), pulse DI , etc. |
||
Frequency range |
0.00 ~ 300.00Hz Note: In the control mode of vector control 1, frequency range from 0.0Hz to 3000.0Hz can be customized according to the customer demand |
||
Start frequency |
0.00 ~ 60.00Hz |
||
Acceleration time and deceleration time |
0.1 ~ 36000s |
||
Dynamic braking |
Braking unit action voltage: 650 ~ 750V; operating time: 100.0s The braking unit can be built-in for V5−H−4T75G and below equipment |
||
DC braking |
DC braking start frequency: 0.00 ~ 300.00Hz DC braking current: constant torque: 0.0 ~ 120.0%, variable torque: 0.0 ~ 90.0% DC braking time: 0.0 ~ 30.0s; DC braking function does not required waiting time to start to realize quick braking |
||
Magnetic flux braking |
Enabled or disabled during deceleration are optional, the default setting is enabled |
||
Unique functions |
Multi-function M key |
The unique multi-function key can be set to frequently used operations: such as JOG, emergency stop, switchover of run command source, switchover of parameters display mode, etc. |
|
Multiple parameters display modes |
Basic parameters display mode, fast parameters display mode, non−factory setting parameters display mode, last changed 10 parameters display mode |
||
Parameters copy |
The standard operation panel can realize the parameters upload, download and display the copy progress. Users can set to forbid overwriting the uploaded parameters |
||
Displayed and hidden parameters group |
The customer can select to display or hide the parameters group by themselves |
||
Dual 485 communication ports |
Dual 485 communication ports support Modbus protocol (RTU). The maximum distance is 500 meters |
||
Operation panel |
Key type or shuttle type operation panel are optional Protection level: IP20 as standard, IP54 as option |
||
Common DC bus |
All series product support common DC bus |
||
Independent duct |
All series product adopts independent duct design and supports the installation of heat-sink outside the cabinet |
||
Universal expansion interface |
Universal expansion board equipped with CPU for supporting customers secondary development: physical interface SPI bus, software protocol Modbus |
||
Expansion card |
Injection molding machine interface card, PG feedback card, air compressor control card, communication adapter card, three phase power supply monitoring card, three phase-sequence detection card, external power rectifying card |
||
Power-On-Self-Test (POST) |
Realizing the POST of internal and peripheral circuits, including motor grounded, abnormal +10V power supply output, analog input and disconnection, etc. |
||
Protection function |
Power supply under-voltage, over-current protection, over-voltage protection, interference protection, abnormal comparison level, motor data identification failure, module(IPM) protection, heat-sink over temperature protection, inverter overload protection, motor overload protection, peripheral protection, abnormal current detection, output short circuit to ground , interruption of power supply when in running status, abnormal input power, output phase loss, abnormal EEPROM protection, abnormal pre-charging contactor detection, temperature sampling disconnection, encoder disconnection, abnormal +10V power supply, abnormal analog input, motor over temperature protection(PTC), abnormal communication, abnormal software version compatibility, abnormal copying, abnormal expansion card connection, terminal mutual exclusion detection, hardware overload protection |
||
Efficiency |
At rated power: 7.5kW and below power class ≥93% 45kW and below power class ≥95% 55kW and above power class ≥98% |
||
Environment |
Operating site |
The product should be mounted vertically in the electric control cabinet with good ventilation. Horizontal or other installation modes are not allowed. The cooling medium is the air. The product should be installed in the environment without dust, corrosive gas, combustible gas, oil mist, steam, drip and free from direct sunlight |
|
Ambient temperature |
−10 to +40ºC, the product must be de-rated rated output current for the ambient temperature between 40ºC to 50ºC, the rated output current must be de-rated for 1% per 1ºC temperature rise |
||
Humidity |
5 to 95%, no condensing |
||
Altitude |
0 to 2000m, the product must be de-rated rated output current for the altitude above 1000 meters, the rated output current must be de-rated for 1% per 100 meters rise |
||
Vibration |
3.5m/s2,2 to 9Hz; 10 m/s2,9 to 200Hz; 15 m/s2,200 to 500Hz |
||
Storage temperature |
−40 to +70ºC |
Installation Dimension
|
|
V5−H−2T0.4G~V5−H−2T2.2G、V5−H−4T7.5G/11L And blow power class
|
|
V5−H−4T11G/15L And above power class
Product Appearance, Installation Dimensions, Approximate Weight
Voltage |
Model |
Appearance, Installation Dimensions(mm) |
Weight (kg) |
|||||||
W |
H |
D |
W1 |
H1 |
D1 |
T1 |
Hole d |
|||
200V |
V5−H−2T0.4G |
118 |
190 |
155 |
105 |
173 |
40.8 |
3 |
5.5 |
1.5 |
V5−H−2T0.75G |
175 |
60.5 |
4 |
2.2 |
||||||
V5−H−2T1.5G |
155 |
40.8 |
3 |
1.5 |
||||||
V5−H−2T2.2G |
175 |
60.5 |
4 |
2.2 |
||||||
400V |
V5−H−4T0.75G/1.5L |
118 |
190 |
155 |
105 |
173 |
40.8 |
3 |
5.5 |
1.5 |
V5−H−4T1.5G/2.2L |
118 |
190 |
175 |
105 |
173 |
60.5 |
4 |
5.5 |
2.6 |
|
V5−H−4T2.2G/3.7L |
||||||||||
V5−H−4T3.7G/5.5L |
||||||||||
V5−H−4T5.5G/7.5L |
155 |
249 |
185 |
136 |
232 |
69 |
8 |
5.5 |
3 |
|
V5−H−4T7.5G/11L |
||||||||||
V5−H−4T11G/15L |
210 |
337 |
200 |
150 |
324 |
88 |
2 |
7 |
8.5 |
|
V5−H−4T15G/18.5L |
||||||||||
V5−H−4T18.5G/22L |
289 |
440 |
220 |
200 |
425 |
88 |
2.5 |
7 |
17 |
|
V5−H−4T22G/30L |
||||||||||
V5−H−4T30G/37L |
||||||||||
V5−H−4T37G/45L |
319 |
575 |
218 |
220 |
553 |
90.5 |
2.5 |
10 |
25 |
|
V5−H−4T45G/55L |
||||||||||
V5−H−4T55G/75L |
404 |
615 |
255 |
270 |
590 |
86.5 |
3.0 |
10 |
35 |
|
V5−H−4T75G/90L |
||||||||||
V5−H−4T90G V5−H−4T110L |
465 |
745 |
325 |
343 |
715 |
151.5 |
3.0 |
12 |
55 |
|
V5−H−4T110G V5−H−4T132L |
||||||||||
V5−H−4T132G V5−H−4T160L |
540 |
890 |
385 |
370 |
855 |
205.5 |
4.0 |
14 |
85 |
|
V5−H−4T160G V5−H−4T185L |
||||||||||
V5−H−4T185G V5−H−4T200L |
||||||||||
V5−H−4T200G V5−H−4T220L |
||||||||||
V5−H−4T220G V5−H−4T250L |
700 |
1010 |
385 |
520 |
977 |
210 |
4.0 |
14 |
125 |
|
V5−H−4T250G V5−H−4T280L |
||||||||||
V5−H−4T280G V5−H−4T315L |
||||||||||
V5−H−4T315G V5−H−4T355L |
810 |
1358 |
425 |
520 |
1300 |
210 |
4.0 |
14 |
215 |
|
V5−H−4T355G V5−H−4T400L |
||||||||||
400V |
V5−H−4T400G V5−H−4T450L |
810 |
1358 |
425 |
520 |
1300 |
210 |
4.0 |
14 |
215 |
V5−H−4T450G V5−H−4T500L |
||||||||||
V5−H−4T500G V5−H−4T560L |
Applications
|
|
|
|
|
|
|
|
|
Representative Industry
Variable frequency drives (VFDs) or AC Drives regulate the rotational force and speed of electric motors by changing the frequency of the input power to the motor. V&T High Performance Universal frequency drive of Shenzhen V&T Technologies Co.,Ltd. are widely used in Printing, Packaging, Petrochemical,Textile, Cable Machinery, Machine Equipment, Food Packaging, Electric Vehicles, Washing Equipment, Plastic Machinery, Metal Products Equipment, Centrifuges and the applications of required open-loop vector etc.