Certification :
CE, EAC, ISO9001, OHSAS18001, TS16949, SGSShipping Port :
ShenzhenPlace of Origin :
ChinaPackage :
Standard Export Package Carton/WoodAvailability :
OEM/ODM, Minmum Order RequestTransportation :
Express · Sea freight · Land freight · Air freightWarranty :
18 MonthsDelivery Time :
5-7 working days for standard series; 7-14 working days for customized AC drivesCustomized :
YESTerm of payment :
T/T, L/C, D/PSample freight payer :
BuyerSample provide :
YES
Product Overview
Item
Description
Product Name
Frequency Inverter/ AC Drive
Model Number
VTSxxx-4TxxxKxx-xxxx
Power Range
0.75kW-500kW
Rated Input Voltage
3 phase 380V/480V
Rated Output Voltage
3 phase 0 to rated input voltage
Input Frequency
50Hz/60Hz
Adaptable Motor
Asynchronous Motor, Synchronous Motor
Control Mode
V/F Control, Vector Control, Sensorless Vector Control, Sensor Vector Control, Vector Torque Control
Communication
Modbus 485 RTU, CAN, Profibus-DP, Profinet, EtherCAT
IP Class
Standard IP20
Overload Capacity
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)
Feature
■ Book Compact Design,Low cost, smaller size and weight;
■ low speed can be open loop control, closed loop control minimum speed of 0.25 Hz 200% torque; closed loop 60000 turn, open loop 110000 rpm
■ Rich selection of communication boards.
■ Support multiple encoder types
■ Compatible with the control of synchronous motors, asynchronous motors, and reluctance motors
■ Multiple language keyboard, friendly interface, reliable and easy to use
Model Explanation
Product Catalogue
VTS□□□−4T□□K□□-□□□□
Rated Power (kW) |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
90 |
110 |
|
Applicable motor (kW) |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
37 |
45 |
55 |
75 |
90 |
110 |
|
Output |
Voltage (V) |
Three−phase 0 to rated input voltage |
||||||||||||
Rated current (A) |
13 |
17 |
24 |
30 |
39 |
45 |
60 |
75 |
91 |
112 |
150 |
176 |
210 |
|
Maximum current (A) |
23 |
31 |
43 |
54 |
70 |
81 |
108 |
135 |
164 |
202 |
270 |
317 |
378 |
|
Overload capability |
150% for 60s, 180% for 10s, 200% for 0.5s, interval: 10 minutes (Inverse time characteristic) |
|||||||||||||
Input |
Rated voltage / frequency |
Three−phase 380V/480V; 50Hz/60Hz |
||||||||||||
Allowable voltage |
323V ~ 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5% |
|||||||||||||
Rated current (A) |
15 |
19 |
26 |
33 |
37 |
42 |
57 |
69 |
89 |
106 |
139 |
164 |
196 |
|
DC reactor |
DC reactor is not built-in |
DC reactor is built-in |
DC reactor is built-in |
|||||||||||
Brake unit |
Built−in as standard |
Built−in as ;optional |
||||||||||||
Protection ;level |
IP20 |
|||||||||||||
Cooling mode |
Force air cooling |
Rated Power (kW) |
132 |
160 |
185 |
200 |
220 |
250 |
280 |
315 |
355 |
400 |
450 |
500 |
|
Applicable motor (kW) |
132 |
160 |
185 |
200 |
220 |
250 |
280 |
315 |
355 |
400 |
450 |
500 |
|
Output |
Voltage (V) |
Three−phase 0 to rated input voltage |
|||||||||||
Rated current (A) |
253 |
304 |
350 |
380 |
426 |
470 |
520 |
600 |
650 |
690 |
775 |
860 |
|
Maximum current ;(A) |
455 |
547 |
630 |
684 |
765 |
846 |
936 |
1080 |
1170 |
1242 |
1395 |
1548 |
|
Overload capability |
150% for 60s, 180% for 10s, 200% for 0.5s, interval: 10 minutes (Inverse time characteristic) |
||||||||||||
Input |
Rated voltage / frequency |
Three−phase 380V/480V; 50Hz/60Hz |
|||||||||||
Allowable voltage |
323V ~ 528V; voltage imbalance ≤3%; allowable frequency fluctuation: ±5% |
||||||||||||
Rated current (A) |
240 |
287 |
326 |
352 |
385 |
437 |
491 |
580 |
624 |
670 |
775 |
840 |
|
DC reactor |
DC reactor is built-in |
||||||||||||
Brake unit |
External |
||||||||||||
Protection level |
IP20 |
||||||||||||
Cooling mode |
Force air cooling |
Technical Specifications
Control characteristics |
Control mode |
Sensor-less control |
Sensor control |
Applicable motor type |
Synchronous motor Asynchronous motor |
Synchronous motor Asynchronous motor |
|
Starting torque |
● Asynchronous motor: 200% of rated torque at 0.25Hz ● Synchronous motor: 150% of rated torque at 1.5% of rated speed |
200% of rated torque at 0 speed |
|
Speed regulation range |
1:200 |
1:5000 |
|
Steady speed precision |
± 0.5% |
± 0.02% |
|
Maximum speed |
VF control: 600Hz ; Vector control: 600 Hz ; Note: Higher frequency products can be customized |
600Hz Note: Higher frequency products can be customized |
|
Torque control |
Y |
Y |
|
Torque control precision |
±5% |
±3% |
|
Torque response time |
<20ms |
<10ms |
|
Positioning control |
N |
Y |
|
Positioning precision |
N |
±1 ;pulse |
|
Product function |
Key function |
Torque limit, speed control, positioning control, motor ;auto tune ;deep flux-weakening ;control, current limit control, over-voltage control, under-voltage control, ;motor ;speed tracing function, droop control, oscillation suppression, random carrier frequency, inertia auto-tune, etc. |
|
Speed reference source |
Modbus communication, Keypad, ;external digital input, analog ;AI1/AI2/AI3, ;high speed pulse input, ;simple PLC, PID, CAN, PROFIBUS DP, PROFINET, EtherCAT, etc. |
||
Dynamic ;brake |
Brake unit action voltage: 650 ~ 750V. The brake unit can be built-in for 110kW and below equipment ● 5.5~30kW: brake unit is built- in as standard. ● 37~110kW: brake unit is built- in as optional. |
||
Communication |
Built-in modbus-RTU communication, the maximum distance up to 500 meters. It can switch to CAN by jumper. EtherCAT, PROFIBUS ;DP and PROFINET are optional. |
||
Keypad |
LED Keypad and LCD Keypad are optional the Keypad can be used as ;remote-control box ;via straight-through wired cable. |
||
Common DC bus |
75kW~160kW: required pre-charge circuit to realized common DC bus Other power level drive: support common DC bus ;directly |
||
Independent air duct |
All series product adopts independent duct design |
||
Protection function |
Power supply under-voltage, over-current protection, over-voltage protection, ;auto-tune fault, module protection, heat-sink overtemperature ;protection, drive overload protection, motor overload protection, peripheral protection, current ;abnormal ;detection, output short-circuit ;to ;ground protection, EEPROM abnormal detection, temperature sampling disconnection, encoder disconnection, analog input abnormal detection, motor overtemperature, communication ;fault, hardware overload protection, etc. |
||
Efficiency |
At rating condition: ● 0.75kW to 7.5kW: ;≥93% ● 11kW to 45kW: ;≥95% ● 55kW and higher power class: ≥98% |
||
Environment |
Operating site |
● Install vertically in a well-ventilated electrical cabinet. Horizontal or other installation methods are not allowed. ● The cooling medium is air. ● Installed in an environment free from direct sunlight, dust, corrosive gases, flammable gases, no oil mist, no steam, no dripping. |
|
Ambient temperature |
● -10~+40℃ ● Derating use when the temperature between 40 to 50℃, the rated output current is reduced by 1% for every 1 °C increasing. |
||
Humidity |
5~95%, ;no condensation is allowed. |
||
Altitude |
● 0~2000 ;meters ● Derating use when the altitude over 1000 meters, the rated output current is reduced by 1% for every 100-meter rising. |
||
Vibration |
● 3.5 m/s2, ;2~9Hz ● 10 m/s2, ;9~200Hz ● 15 m/s2, ;200~500Hz |
||
Storage temperature |
−40~+70℃. |
Installation dimension
|
|
|
185kW~500kW
The base dimensions for VTS□□□−4T250K to VTS□□□−4T315K (The base is optional)
Base dimensions (from ;250kW ;to 315kW)
The base dimensions for VTS□□□−4T355K to VTS□□□−4T500K (The base is optional)
Base dimensions (from 355kW ;to ;500kW)
Voltage |
Model |
Outline and mounting dimension (mm) |
Weight ;(KG) |
||||||
W |
H |
D |
W1 |
H1 |
T1 |
⌀d |
|||
400V |
VTS□□□−4T5.5K |
100 |
291 |
220 |
60 |
275 |
4.5 |
5 |
3.5 |
VTS□□□−4T7.5K |
|||||||||
VTS□□□−4T11K |
|||||||||
VTS□□□−4T15K |
|||||||||
VTS□□□−4T18.5K |
145 |
412 |
260 |
120 |
396 |
1.0 |
7 |
9.5 |
|
VTS□□□−4T22K |
|||||||||
VTS□□□−4T30K |
|||||||||
VTS□□□−4T37K |
210 |
498 |
290 |
150 |
478 |
3.0 |
10 |
20.5 |
|
VTS□□□−4T45K |
|||||||||
VTS□□□−4T55K |
|||||||||
VTS□□□−4T75K |
290 |
705 |
285 |
240 |
683 |
3.0 |
10 |
48.5 |
|
VTS□□□−4T90K |
|||||||||
VTS□□□−4T110K |
|||||||||
VTS□□□−4T132K |
315 |
970 |
325 |
250 |
946 |
3.0 |
12 |
78.2 |
|
VTS□□□−4T160K |
|||||||||
VTS□□□−4T185K |
420 |
1080 |
325 |
340 |
1050 |
3.5 |
14 |
99 |
|
VTS□□□−4T200K |
|||||||||
VTS□□□−4T220K |
|||||||||
VTS□□□−4T250K |
512 |
1320 |
355 |
376 |
1286 |
4 |
16 |
The base can be customized with different weights |
|
VTS□□□−4T280K |
|||||||||
VTS□□□−4T315K |
|||||||||
VTS□□□−4T355K |
699 |
1432 |
407 |
340 |
1395 |
4 |
14 |
||
VTS□□□−4T400K |
|||||||||
VTS□□□−4T450K |
|||||||||
VTS□□□−4T500K |
Applications
|
|
|
|
|
|
|
|
|
Representative Industry
Printing Packaging, Petrochemical, Textile, Cable Machinery, Food Packaging, Electric Vehicles, Plastic Machinery, Metal Products Equipment, Centrifuges, Universal fields and High-end applications requiring closed-loop vector or torque control.